Features
- Aerator type: Integrated aerator, Aerator includes flow restrictor, Adjustable flow angle
- Connection type: Flexible connection pipes
- Electronic components: Autofocus sensor, Solenoid valve, Includes power supply
- Lever/Handle Type: Temperature Control Handle
- Mechanical parts: Mixing valve for manual temperature control, Check valves, Debris filters
- Special features: Inner body made of dezincification-resistant brass, Software settings can be changed via Oras App (Bluetooth), Flow rate can be permanently changed to cold or pre-mixed water
- Spout type: Fixed spout, Cast construction
- Color: Chrome
- Temperature controls: Temperature control limiter (retrofitable)
Software settings
- Post-flow time: 3 s (1-20 s)
- Automatic flushing: off (off/1-120 h)
- Automatic flushing time: 30 s (1-1800 s)
- Max. flow time: 2 min (1 - 1800 s)
Flow attributes
- Flow rate at 300 kPa (with flow restrictor): 0.08 l/s
- Pressure loss with flow (0.1 l/s): 200 kPa
Technical features
- Backflow protection (EN1717): AA
- Connection size: G3/8
- Hot water max. +70°C
- Material: Brass
- Reach: 105 mm
- Operating pressure: 100 - 1000 kPa
Electronic attributes
- Bluetooth version: 4.x (D034445)
- Electrical connection: 230 / 9 V
Articles
- EU Directives: Radio Equipment Directive 2014/53/EU, Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU, RoHS Directive 2011/65/EU
- EN standard: EN 15091, ETSI EN 301 489-1 V1.9.2 , ETSI EN 300 328 v2.2.2 , EN 61000-6-1:2007 , EN 61000-6-3:2007+A1:2011+AC:2012 , EN 60335-1:2012+A11+A13+A1+A14+A2+A15:2021, Part 19.11.4
- Sound class: I (ISO 3822)
- Protection class: IP 55 / transformer IP 20
Approvals and Declarations
- STF certificate: EUFI29-21003824-TH
- KIWA SE: 1745
Responsibility
EPD module A1 (kg CO2 eq.): 9.37
EPD module A1-A3 (kg CO2 eq.): 10.30
EPD module A2 (kg CO2 eq.): 0.43
EPD module A3 (kg CO2 eq.): 0.50
EPD module A4 (kg CO2 eq.): 0.38
EPD module B7 (kg CO2 eq.): 2064.00
EPD module C2 (kg CO2 eq.): 0.02
EPD module C3 (kg CO2 eq.): 0.02
EPD module C4 (kg CO2 eq.): 0.29
EPD module D (kg CO2 eq.): -7.51